Skip to main content
zerologs
Warning· MBB / BMS log file

Cell Imbalance

Cell voltage delta (B field) exceeds threshold (typically >100mV)

Battery/BMSSource: BMSLog file condition
Last updated: 30 July 2026

What it means

Warning: Monitor the situation, may self-resolve.

Likely causes

  • One or more cells degrading faster
  • BMS balancing not completing
  • Long period without full charge

What to do

  1. 1Perform full 100% charge to allow balancing
  2. 2Monitor B field over several charge cycles
  3. 3If B >150mV persists, dealer inspection

Which bikes use this table

Recorded in the binary log rather than shown on the dash. Every generation writes them.

Questions

What does "Cell Imbalance" mean in a Zero log?

Cell voltage delta (B field) exceeds threshold (typically >100mV). It is written by the BMS. It is classed as warning: monitor the situation, may self-resolve.

What should I do about it?

Perform full 100% charge to allow balancing. Monitor B field over several charge cycles. If B >150mV persists, dealer inspection.

See when this happened on your bike

A dash code tells you the fault; the log tells you the pack temperature, the state of charge and the ten minutes leading up to it.

Upload a log

Community reference: ZeroManual wiki entry